NTC Sensor Module TAF502G3950FBHA30-G

NTC Sensor Module TAF502G3950FBHA30-G

The NTC Sensor Module is primarily used in industrial and medical equipment

Product Name NTC Sensor Module
Product series E08-50011-20120
Product model TAF502G3950FBHA30-G

Product Categories

Need consultation?

Share your idea, We’ll find solution for you within 24 hours

Product Drawing

Electrical Characteristic

Item Symbol Test Conditions Min. Nor. Max. Unit
Resistance At 25℃ R25 Ta=25℃±0.05℃ PT≦0.1mW 4.90=0 5.00 5.10
Resistance At 50℃ R50 Ta=50℃±0.05℃ PT≦0.1mW / 1.794 /
B Value B25/50 (1779.707* LnK) 3910.5 3950 3989.5 K
Thermal Dissipation Constant δ Ta=25℃(in air) / 5.0 / ‘mW/℃
Response Time-In liquid τ Ta=25±0.5℃ / / 15 Sec
Hi-Pot Test / AC1500V 3Sec / / 2.0 m A
Insulation test / DC500V 5Sec 100 / /

Ratings

Item Specification Unit
Product Working Temp.Range -30 ~ +80
NTC Working Temp.Range -40 ~ +125

Mechanical Tests

Item Pass Criteria Test Conditions
Pull test No loosening No deformation Terminal should not be pull off from the Connector with a force of less than 1KG(9.8N)
Drop Test Appearance should be no visible damage Drop on a 10mm thick wooden board from a height of 1m for 5 times

Storage Conditions

Ambicnt Temperature: -10℃~+40℃

Relative Humidity: ≦75%RH

Keep away from corrosive atmosphere and sunlight

Period of Storage: 1 year

Product Application Conditions

1.Maximum service temperature and maximum power in application should not exceeds specification listed in Product Specification

2.Much be handled with care when moving and installing the product

3.Product should not be used when deformed or rusty casing is observed on product

4.Product should not be used when broken housing ,or excessive deformation on housing is observed

5.Avoid excessive temperature fluctuation when operating the product in its operational temperature range

6.Do not apply excessive shock and vibration on product

7.Do not pull or bend the lead wire excessively

8.Do not use in any ambient with corrosiven gas (CO2,NH3,Sox,Nox) Do not use in any ambient with electrolytic solution with brine,acid,alkaline and organic

9.Do not use in environment with water.high moisture,and high corrosive solution

10.Current throught NTC element will cause self-heating,and may affect the measurement

11.This product belongs to surface appressed type sensor temperature, when using, need to make bottom plane fully and heating.

If there is anything question and concerns, please contact to our sales representative and engineer